{"id":3910,"date":"2026-08-03T13:27:00","date_gmt":"2026-08-03T05:27:00","guid":{"rendered":"https:\/\/ksnrsolar.com\/brownfield-degraded-soil-pv-racking\/"},"modified":"2026-08-03T13:27:00","modified_gmt":"2026-08-03T05:27:00","slug":"brownfield-degraded-soil-pv-racking","status":"publish","type":"post","link":"https:\/\/ksnrsolar.com\/it\/brownfield-degraded-soil-pv-racking\/","title":{"rendered":"Brownfield-Site PV Support &#038; Restored-Land Racking for Degraded Soil"},"content":{"rendered":"<style>\n.el-sec{background:#fff;border-radius:8px;box-shadow:0 1px 4px rgba(20,40,80,.08);padding:34px 42px;margin:0 auto 22px;max-width:1020px;box-sizing:border-box}\n.el-h{color:#1E293B;margin:0 0 14px}\nh2.el-h{font-size:26px;text-align:center;border-left:none;padding-left:0;line-height:1.3;margin-bottom:22px}\nh2.el-h::after{content:'';display:block;width:60px;height:3px;background:#F9960E;margin:12px auto 0;border-radius:2px}\nh3.el-h{font-size:19px}\n.el-hero{padding:0;overflow:hidden}\n.el-overlay{padding:48px 38px;text-align:center}\n.el-overlay .el-check{display:inline-block;text-align:left}\n.el-row{display:flex;gap:16px;align-items:stretch;flex-wrap:wrap}\n.el-col{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;box-sizing:border-box}\n.el-btn{display:inline-block;background:#0097B4;color:#fff !important;padding:10px 26px;border-radius:5px;text-decoration:none;font-weight:600;font-size:15px}\n.el-check{list-style:none;margin:10px 0;padding:0}\n.el-check li{padding:5px 0 5px 26px;position:relative}\n.el-check li::before{content:'\u2713';position:absolute;left:2px;color:#1E8A5F;font-weight:700}\n.el-box{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;margin:8px 0}\n.el-box-icon{font-size:24px;margin-bottom:6px}\n.el-box h4{color:#1E293B;margin:0 0 6px;font-size:16px}\n.el-box p{font-size:14px;color:#334155;margin:0}\n.el-acc details{border:1px solid #D1D5DB;border-radius:6px;margin:0 0 10px;background:#F9FAFB}\n.el-acc summary{padding:13px 18px;cursor:pointer;font-weight:600;color:#1E293B}\n.acc-body{padding:4px 18px 14px;font-size:14.5px;color:#334155}\n.el-cta{text-align:center}\n.el-cta .el-h{color:#fff;border-left:none;padding-left:0}\n.el-cta .el-btn{background:#1E293B}.el-cta .el-text{color:#fff}.el-cta .el-text p{color:rgba(255,255,255,.92)}\n.el-sec table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14.5px}\n.el-sec th,.el-sec td{border:1px solid #D1D5DB;padding:9px 12px;text-align:left;vertical-align:top}\n.el-sec th{background:#F0F5FA;color:#1E293B}\n.el-text p{margin:0 0 10px}\n.el-text ul{margin:0 0 10px 22px}\n.el-text a{color:#0097B4}\n.el-band{background:#F0F5FA;border-radius:8px;max-width:1020px;margin:0 auto 22px;padding:18px 30px;font-size:15px;box-sizing:border-box}\n.el-band p{margin:0}\n.el-media{display:flex;gap:30px;align-items:center}\n.el-media.rev{flex-direction:row-reverse}\n.el-media-txt{flex:1.15;min-width:0}\n.el-media-img{flex:1;min-width:0}\n.el-media-img img{width:100%;height:auto;display:block;border-radius:8px;box-shadow:0 2px 10px rgba(20,40,80,.14)}\nul.el-two{column-count:2;column-gap:44px}\nul.el-two li{break-inside:avoid}\n@media (max-width:767px){.el-row{flex-direction:column}.el-col{flex:none !important;max-width:100% !important}.el-sec{padding:22px 18px}.el-overlay{padding:32px 20px}.el-media,.el-media.rev{flex-direction:column;align-items:stretch}ul.el-two{column-count:1}.el-band{padding:14px 18px}}\n.el-btn:hover{background:#F9960E}<\/style>\n<section class=\"el-sec el-hero\" style=\"background-image:url(\/wp-content\/uploads\/2026\/09\/pv-sub-brownfield-degraded-soil-pv-racking-1.jpg);background-size:cover;background-position:center;\">\n<div class=\"el-overlay\" style=\"background:rgba(255,255,255,0.82);\">\n<h2 class=\"el-h\">Brownfield-Site PV Support &#038; Restored-Land Racking for Degraded Soil<\/h2>\n<div class=\"el-text\">\n<p>Brownfield and degraded-soil PV reuses industrial land where contamination and broken ground shape method statements: no-excavation foundations, worker protection, and coordination with remediation obligations. This page is for buyers converting legacy sites into generation.<\/p>\n<p>This page is written for procurement engineers, EPC structure leads and technical buyers evaluating racking supply for Reclamation \/ Brownfield projects.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/it\/contact-us\/#contactpopupform\">Richiedi un preventivo rapido<\/a><\/p>\n<\/div>\n<\/section>\n<div class=\"el-band\">\n<div class=\"el-text\">\n<p>This page is one of several in our reclamation \/ brownfield segment. See the full range of structures, foundations and configurations on the <a href=\"\/it\/brownfield-solar-projects\/\">PV Racking for Reclaimed, Brownfield &#038; Post-Mining Land<\/a> pagina centrale.<\/p>\n<\/div>\n<\/div>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Why Reclamation \/ Brownfield sites are demanding<\/h2>\n<div class=\"el-text\">\n<p>Mining subsidence, landfills and brownfields are where PV earns its land-use reputation: degraded ground becomes a revenue asset. The engineering reality is ground that moves or cannot be penetrated &#8211; so foundations become adjustable, ballasted or monitoring-instrumented, and landfill caps are never breached.<\/p>\n<p><strong>Le sfide del sito che affrontiamo con soluzioni ingegneristiche:<\/strong><\/p>\n<\/div>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>Sfida 01<\/h4>\n<p>Gas and settlement monitoring infrastructure must remain accessible<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>Sfida 02<\/h4>\n<p>Permit conditions often require restorability and monitoring commitments<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>Sfida 03<\/h4>\n<p>Subsidence continues for years; fixed foundations crack or rack as ground deforms<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u26a1<\/div>\n<h4>Sfida 04<\/h4>\n<p>Landfill caps cannot be penetrated &#8211; ballast is the only legal foundation<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>Sfida 05<\/h4>\n<p>Contaminated soils constrain excavation and require protection plans<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>Sfida 06<\/h4>\n<p>Legacy foundations and debris complicate piling<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>Sfida 07<\/h4>\n<p>Remediation obligations may coexist with construction<\/p>\n<\/div>\n<\/div>\n<\/section>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Requisiti ingegneristici e basi di progettazione<\/h2>\n<ul class=\"el-check\">\n<li>Ballasted foundations engineered for cap load limits (kPa ceilings)<\/li>\n<li>No-excavation installation: ground screws excluded on caps, concrete avoided on tailings<\/li>\n<li>Gas-compatible detailing where methane management systems exist<\/li>\n<li>Ground-movement monitoring with survey points tied to structure condition<\/li>\n<\/ul>\n<div class=\"el-text\">\n<p><strong>Guida alla selezione:<\/strong> Map legacy foundations and contamination zones before pricing; require the method statement to reference your environmental report explicitly.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-media\">\n<div class=\"el-media-txt\">\n<h3 class=\"el-h\">Soluzione ingegnerizzata<\/h3>\n<div class=\"el-text\">\n<ul>\n<li>Reference programs from operating subsidence and landfill plants<\/li>\n<li>Subsidence package: adjustable heads, monitoring points, re-leveling methodology<\/li>\n<li>Ballast systems sized against cap bearing limits with geotextile separation<\/li>\n<li>Contaminated-land installation method statements and PPE requirements<\/li>\n<li>Coordination with gas and settlement monitoring infrastructure<\/li>\n<\/ul>\n<p>In relazione a questa specifica applicazione, forniamo inoltre:<\/p>\n<ul>\n<li>No-excavation foundation kits: screws, anchors or ballast selected per ground condition<\/li>\n<li>Contaminated-land method statements with PPE and handling protocols<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"el-media-img\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/09\/pv-sub-brownfield-degraded-soil-pv-racking-2.jpg\" alt=\"Brownfield PV support solar racking - engineered structure detail\" loading=\"lazy\"><\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Metodo di installazione e produttivit\u00e0 del sito<\/h3>\n<div class=\"el-text\">\n<p>Prima di confrontare il prezzo dell&#039;acciaio, informatevi sulle modalit\u00e0 di installazione delle strutture. I nostri sistemi si installano con attrezzature edili standard: non sono necessari utensili proprietari n\u00e9 saldature in loco nelle fasi critiche. I pali vengono infissi o avvitati con attrezzature standard del settore e le dime di fissaggio mantengono le tolleranze di ancoraggio; i tavoli arrivano preassemblati in kit, sequenziati secondo il vostro piano di impilamento; il bulloneria a coppia controllata, con valori di coppia forniti, sostituisce le saldature; e le regolazioni delle guide compensano le irregolarit\u00e0 del terreno dovute ai lavori di livellamento. Forniamo disegni di installazione, un manuale dettagliato, tabelle di accettazione di coppia e tolleranze e supporto remoto durante il periodo di installazione. Su richiesta, un supervisore dell&#039;installazione former\u00e0 la vostra squadra sui primi blocchi.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Parametri di riferimento del settore<\/h3>\n<div class=\"el-text\">\n<p>I benchmark riportati di seguito sono progetti di riferimento del settore, documentati pubblicamente, di tipologia e dimensioni comparabili, citati a scopo illustrativo delle migliori pratiche ingegneristiche. Non rappresentano il nostro portfolio di progetti realizzati; i progetti di riferimento per la vostra configurazione vengono forniti insieme ai preventivi.<\/p>\n<ul class=\"el-two\">\n<li>A 6 GW-class composite base on Ningxia coal-mining subsidence land, converting deformed ground into PV land with monitoring and adjustable foundations. The landmark subsidence-area siting reference.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Standard e conformit\u00e0<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Landfill cap protection regulations (local; absolute requirement)<\/li>\n<li>Geotechnical settlement monitoring practice<\/li>\n<li>ISO 12944 coatings for contaminated and gaseous soils<\/li>\n<li>Structural ballast verification with bearing-limit documentation<\/li>\n<li>Gestione della qualit\u00e0 della produzione secondo la norma ISO 9001; tracciabilit\u00e0 dei lotti<\/li>\n<li>Documentazione CE \/ EN 1090 laddove richiesto dai mercati di destinazione<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Fattori che influenzano il budget e i tempi di consegna<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Ballast tonnage drives cost on caps: structure weight per MW matters more than steel price<\/li>\n<li>Adjustable-head systems add modest capex versus one re-leveling cycle avoided<\/li>\n<li>Monitoring commitments are opex; price them into the business case<\/li>\n<li>Lead time: 8-14 weeks; ballast supply logistics often set the pace<\/li>\n<li>I preventivi specificano esplicitamente il tipo di acciaio, la massa di zinco e il sistema di rivestimento; gli Incoterms e i piani di container sono quotati fino al porto di destinazione.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Confronto dei preventivi dei fornitori<\/h3>\n<div class=\"el-text\">\n<p>I preventivi per lo stesso sito possono differire del 30% ed entrambi devono essere onesti: la differenza si nasconde nelle ipotesi dichiarate. Quando si confrontano le offerte, \u00e8 importante normalizzare cinque elementi: grado dell&#039;acciaio e peso delle sezioni (rotaie pi\u00f9 leggere con spaziatura pi\u00f9 stretta non sono sempre pi\u00f9 economiche per megawatt quando aumenta il numero di pali); massa di zinco e sistema di rivestimento in base alla classe di corrosivit\u00e0; ambito delle fondazioni: solo pali o pali pi\u00f9 ancoraggi, capitelli e accessori di livellamento; ferramenta di collegamento: classi di bulloni e se sono specificati i valori di coppia; e logistica: utilizzo dei container, porto di scarico e responsabilit\u00e0 del trasporto interno. Un&#039;offerta che indica tutti e cinque gli elementi \u00e8 comparabile; un&#039;offerta che li omette rappresenta uno sconto che pagherete in seguito.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Domande frequenti<\/h2>\n<div class=\"el-acc\">\n<details>\n<summary>What foundation works on unpredictable brownfield ground?<\/summary>\n<div class=\"acc-body\">Screw piles and anchors adapt zone by zone, with ballast where penetration is impossible. The mix is priced from a legacy-features survey, not assumptions.<\/div>\n<\/details>\n<details>\n<summary>How is contamination handled during installation?<\/summary>\n<div class=\"acc-body\">No-excavation methods minimize soil contact; where soil is disturbed, handling protocols per your environmental report apply. The method statement is contract scope.<\/div>\n<\/details>\n<details>\n<summary>Do remediation schedules conflict with construction?<\/summary>\n<div class=\"acc-body\">They can be sequenced &#8211; remediated zones first, or zones without obligations. The phasing plan coordinates both timelines.<\/div>\n<\/details>\n<\/div>\n<h3 class=\"el-h\">Altre domande poste dagli acquirenti<\/h3>\n<div class=\"el-acc\">\n<details>\n<summary>A chi appartiene il progetto strutturale? Possiamo modificarlo?<\/summary>\n<div class=\"acc-body\">I disegni esecutivi specifici per il progetto vengono forniti per il vostro utilizzo; il sistema strutturale sottostante rimane di nostra propriet\u00e0 intellettuale. Le modifiche da parte del cliente sono benvenute tramite il nostro ufficio tecnico: verifichiamo il percorso di carico e riemettiamo i disegni interessati, poich\u00e9 tagli in cantiere a binari o connessioni non approvati invalidano la garanzia e possono compromettere il progetto.<\/div>\n<\/details>\n<details>\n<summary>Come vengono gestite le modifiche agli ordini durante la produzione?<\/summary>\n<div class=\"acc-body\">Le modifiche vengono valutate in base al programma di produzione: prima del taglio del materiale, a un costo quasi nullo; dopo il taglio ma prima della verniciatura, al costo di sostituzione del materiale; dopo la zincatura, al costo di rifacimento. Ogni modifica viene confermata per iscritto con una data di consegna rivista prima dell&#039;esecuzione. Questo processo serve a tutelare le tempistiche di entrambe le parti e il nostro registro delle richieste di modifica viene allegato al dossier di progetto.<\/div>\n<\/details>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Cosa includere nella richiesta di offerta (RFQ)<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Environmental\/contamination report<\/li>\n<li>Legacy structure and foundation survey<\/li>\n<li>Remediation obligations and schedule<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Dalla richiesta di offerta alla messa in servizio: il nostro metodo di lavoro<\/h3>\n<div class=\"el-text\">\n<p>Due fattori determinano il successo di un ordine di scaffalature: gli accordi presi prima della produzione e la documentazione effettuata durante la stessa. Prima della produzione, ci allineiamo su cinque elementi fondamentali: la base progettuale strutturale, il tipo di fondazione per zona di terreno, la classe di protezione dalla corrosione, l&#039;interfaccia tra i moduli e la sequenza di consegna. Durante la produzione, ogni lotto genera una documentazione che potete fornire al vostro finanziatore o committente senza bisogno di traduzione: certificati di fabbricazione, misurazioni del rivestimento, verifica della coppia di serraggio, conteggio dei pezzi imballati. Dopo la consegna, restiamo in contatto con voi: forniamo assistenza per l&#039;installazione, supporto per la prima ispezione al momento della consegna e un elenco di pezzi di ricambio dimensionato in base alla durata di vita utile del vostro sito, anzich\u00e9 basarci su un catalogo predefinito. Chiedete ai clienti precedenti come sono state gestite le richieste di modifica in corso di produzione; questa \u00e8 la vera prova di un fornitore.<\/p>\n<p>Inviate i documenti alla nostra casella di posta elettronica dedicata all&#039;ingegneria; un ingegnere strutturale vi risponder\u00e0 entro un giorno lavorativo \u2013 non una risposta commerciale, ma una risposta tecnica.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Qualit\u00e0, garanzia e consegna<\/h3>\n<div class=\"el-text\">\n<p>Ogni lotto viene spedito con certificati di produzione, registri dello spessore del rivestimento e documentazione relativa ai bulloni; le saldature sono conformi alle classi di esecuzione EN 1090 o AISC. La garanzia sulla struttura \u00e8 di 10 anni, con una vita utile prevista di 25-30 anni, e i pacchetti di ricambi sono documentati in modo che le riparazioni al dodicesimo anno non dipendano dalla memoria del primo anno.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Documentazione che riceverai<\/h3>\n<div class=\"el-text\">\n<p>Gli acquirenti che confrontano i fornitori dovrebbero valutare la completezza della documentazione, perch\u00e9 presentare reclami \u00e8 facile, ma la documentazione non lo \u00e8. Noi forniamo: documenti di base di progettazione che specificano esplicitamente standard, casi di carico e fattori di sicurezza; registri di qualit\u00e0 a livello di lotto (acciaio, zincatura, elementi di fissaggio) conservati per tutta la durata della garanzia; manuali di installazione e manutenzione redatti per le squadre in cantiere, non per il marketing; termini di garanzia che specificano cosa \u00e8 coperto, per quanto tempo e la procedura di reclamo; e dossier di fine progetto adatti al passaggio al vostro appaltatore di O&amp;M. Per gli acquirenti di pi\u00f9 progetti, manteniamo uno storico della documentazione per ogni sito, in modo che le estensioni all&#039;ottavo anno facciano riferimento alle ipotesi del primo anno anzich\u00e9 ripartire da zero.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Pianificazione della durata di servizio e della manutenzione<\/h2>\n<div class=\"el-text\">\n<p>La scelta di una struttura di scaffalatura \u00e8 una decisione che dura trent&#039;anni, e il primo intervento di manutenzione \u00e8 il momento in cui la scarsa qualit\u00e0 dei componenti si fa sentire. Progettiamo sistemi di rivestimento in base alla classe di corrosivit\u00e0 del vostro sito: C2 per zone interne aride, C3-C4 per la maggior parte delle aree costiere e agricole, C5 per ambienti industriali e marini ad alta esposizione. Indichiamo per iscritto il tempo previsto per il primo intervento di manutenzione. La selezione dei bulloni segue la stessa logica: elementi di fissaggio ad alta resistenza rivestiti con coppia di serraggio controllata, poich\u00e9 l&#039;utilizzo di componenti eterogenei \u00e8 la causa pi\u00f9 comune di corrosione precoce riscontrata nelle ispezioni in loco. Un kit di ricambi dimensionato in base all&#039;ambiente di lavoro viene spedito insieme all&#039;ordine.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Termini di ricerca per cui \u00e8 stata progettata questa pagina<\/h2>\n<div class=\"el-text\">\n<p>brownfield PV support, degraded soil solar mount, waste dump PV support, restored land photovoltaic racking, solar bracket for brownfield site.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec el-cta\" style=\"background-color:#0097B4;\">\n<h2 class=\"el-h\">Pronti a discutere del vostro progetto?<\/h2>\n<div class=\"el-text\">\n<p>Send the environmental report &#8211; we will return a no-excavation foundation plan with the method statements that satisfy your regulator.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/it\/contact-us\/#contactpopupform\">Richiedi un preventivo<\/a><\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Specifying Brownfield solar racking? This page shows which configuration fits your site, what drives delivered cost, and which QA evidence to demand.<\/p>","protected":false},"author":1,"featured_media":3311,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[354,319],"tags":[356],"class_list":["post-3910","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-brownfield-reclaimed-post-mining-solar-projects","category-site-types","tag-reclaimed-brownfield-long-tail-page-pv-mounting-system"],"_links":{"self":[{"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/posts\/3910","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/comments?post=3910"}],"version-history":[{"count":0,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/posts\/3910\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/media\/3311"}],"wp:attachment":[{"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/media?parent=3910"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/categories?post=3910"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ksnrsolar.com\/it\/wp-json\/wp\/v2\/tags?post=3910"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}