{"id":3910,"date":"2026-08-03T13:27:00","date_gmt":"2026-08-03T05:27:00","guid":{"rendered":"https:\/\/ksnrsolar.com\/brownfield-degraded-soil-pv-racking\/"},"modified":"2026-08-03T13:27:00","modified_gmt":"2026-08-03T05:27:00","slug":"brownfield-degraded-soil-pv-racking","status":"publish","type":"post","link":"https:\/\/ksnrsolar.com\/fr\/brownfield-degraded-soil-pv-racking\/","title":{"rendered":"Brownfield-Site PV Support &#038; Restored-Land Racking for Degraded Soil"},"content":{"rendered":"<style>\n.el-sec{background:#fff;border-radius:8px;box-shadow:0 1px 4px rgba(20,40,80,.08);padding:34px 42px;margin:0 auto 22px;max-width:1020px;box-sizing:border-box}\n.el-h{color:#1E293B;margin:0 0 14px}\nh2.el-h{font-size:26px;text-align:center;border-left:none;padding-left:0;line-height:1.3;margin-bottom:22px}\nh2.el-h::after{content:'';display:block;width:60px;height:3px;background:#F9960E;margin:12px auto 0;border-radius:2px}\nh3.el-h{font-size:19px}\n.el-hero{padding:0;overflow:hidden}\n.el-overlay{padding:48px 38px;text-align:center}\n.el-overlay .el-check{display:inline-block;text-align:left}\n.el-row{display:flex;gap:16px;align-items:stretch;flex-wrap:wrap}\n.el-col{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;box-sizing:border-box}\n.el-btn{display:inline-block;background:#0097B4;color:#fff !important;padding:10px 26px;border-radius:5px;text-decoration:none;font-weight:600;font-size:15px}\n.el-check{list-style:none;margin:10px 0;padding:0}\n.el-check li{padding:5px 0 5px 26px;position:relative}\n.el-check li::before{content:'\u2713';position:absolute;left:2px;color:#1E8A5F;font-weight:700}\n.el-box{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;margin:8px 0}\n.el-box-icon{font-size:24px;margin-bottom:6px}\n.el-box h4{color:#1E293B;margin:0 0 6px;font-size:16px}\n.el-box p{font-size:14px;color:#334155;margin:0}\n.el-acc details{border:1px solid #D1D5DB;border-radius:6px;margin:0 0 10px;background:#F9FAFB}\n.el-acc summary{padding:13px 18px;cursor:pointer;font-weight:600;color:#1E293B}\n.acc-body{padding:4px 18px 14px;font-size:14.5px;color:#334155}\n.el-cta{text-align:center}\n.el-cta .el-h{color:#fff;border-left:none;padding-left:0}\n.el-cta .el-btn{background:#1E293B}.el-cta .el-text{color:#fff}.el-cta .el-text p{color:rgba(255,255,255,.92)}\n.el-sec table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14.5px}\n.el-sec th,.el-sec td{border:1px solid #D1D5DB;padding:9px 12px;text-align:left;vertical-align:top}\n.el-sec th{background:#F0F5FA;color:#1E293B}\n.el-text p{margin:0 0 10px}\n.el-text ul{margin:0 0 10px 22px}\n.el-text a{color:#0097B4}\n.el-band{background:#F0F5FA;border-radius:8px;max-width:1020px;margin:0 auto 22px;padding:18px 30px;font-size:15px;box-sizing:border-box}\n.el-band p{margin:0}\n.el-media{display:flex;gap:30px;align-items:center}\n.el-media.rev{flex-direction:row-reverse}\n.el-media-txt{flex:1.15;min-width:0}\n.el-media-img{flex:1;min-width:0}\n.el-media-img img{width:100%;height:auto;display:block;border-radius:8px;box-shadow:0 2px 10px rgba(20,40,80,.14)}\nul.el-two{column-count:2;column-gap:44px}\nul.el-two li{break-inside:avoid}\n@media (max-width:767px){.el-row{flex-direction:column}.el-col{flex:none !important;max-width:100% !important}.el-sec{padding:22px 18px}.el-overlay{padding:32px 20px}.el-media,.el-media.rev{flex-direction:column;align-items:stretch}ul.el-two{column-count:1}.el-band{padding:14px 18px}}\n.el-btn:hover{background:#F9960E}<\/style>\n<section class=\"el-sec el-hero\" style=\"background-image:url(\/wp-content\/uploads\/2026\/09\/pv-sub-brownfield-degraded-soil-pv-racking-1.jpg);background-size:cover;background-position:center;\">\n<div class=\"el-overlay\" style=\"background:rgba(255,255,255,0.82);\">\n<h2 class=\"el-h\">Brownfield-Site PV Support &#038; Restored-Land Racking for Degraded Soil<\/h2>\n<div class=\"el-text\">\n<p>Brownfield and degraded-soil PV reuses industrial land where contamination and broken ground shape method statements: no-excavation foundations, worker protection, and coordination with remediation obligations. This page is for buyers converting legacy sites into generation.<\/p>\n<p>This page is written for procurement engineers, EPC structure leads and technical buyers evaluating racking supply for Reclamation \/ Brownfield projects.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/fr\/contact-us\/#contactpopupform\">Obtenez un devis rapide<\/a><\/p>\n<\/div>\n<\/section>\n<div class=\"el-band\">\n<div class=\"el-text\">\n<p>This page is one of several in our reclamation \/ brownfield segment. See the full range of structures, foundations and configurations on the <a href=\"\/fr\/brownfield-solar-projects\/\">PV Racking for Reclaimed, Brownfield &#038; Post-Mining Land<\/a> Page centrale.<\/p>\n<\/div>\n<\/div>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Why Reclamation \/ Brownfield sites are demanding<\/h2>\n<div class=\"el-text\">\n<p>Mining subsidence, landfills and brownfields are where PV earns its land-use reputation: degraded ground becomes a revenue asset. The engineering reality is ground that moves or cannot be penetrated &#8211; so foundations become adjustable, ballasted or monitoring-instrumented, and landfill caps are never breached.<\/p>\n<p><strong>D\u00e9fis du site que nous relevons par la conception\u00a0:<\/strong><\/p>\n<\/div>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>D\u00e9fi 01<\/h4>\n<p>Gas and settlement monitoring infrastructure must remain accessible<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 02<\/h4>\n<p>Permit conditions often require restorability and monitoring commitments<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 03<\/h4>\n<p>Subsidence continues for years; fixed foundations crack or rack as ground deforms<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u26a1<\/div>\n<h4>D\u00e9fi 04<\/h4>\n<p>Landfill caps cannot be penetrated &#8211; ballast is the only legal foundation<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>D\u00e9fi 05<\/h4>\n<p>Contaminated soils constrain excavation and require protection plans<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 06<\/h4>\n<p>Legacy foundations and debris complicate piling<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 07<\/h4>\n<p>Remediation obligations may coexist with construction<\/p>\n<\/div>\n<\/div>\n<\/section>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Exigences techniques et base de conception<\/h2>\n<ul class=\"el-check\">\n<li>Ballasted foundations engineered for cap load limits (kPa ceilings)<\/li>\n<li>No-excavation installation: ground screws excluded on caps, concrete avoided on tailings<\/li>\n<li>Gas-compatible detailing where methane management systems exist<\/li>\n<li>Ground-movement monitoring with survey points tied to structure condition<\/li>\n<\/ul>\n<div class=\"el-text\">\n<p><strong>Conseils de s\u00e9lection\u00a0:<\/strong> Map legacy foundations and contamination zones before pricing; require the method statement to reference your environmental report explicitly.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-media\">\n<div class=\"el-media-txt\">\n<h3 class=\"el-h\">Solution technique<\/h3>\n<div class=\"el-text\">\n<ul>\n<li>Reference programs from operating subsidence and landfill plants<\/li>\n<li>Subsidence package: adjustable heads, monitoring points, re-leveling methodology<\/li>\n<li>Ballast systems sized against cap bearing limits with geotextile separation<\/li>\n<li>Contaminated-land installation method statements and PPE requirements<\/li>\n<li>Coordination with gas and settlement monitoring infrastructure<\/li>\n<\/ul>\n<p>Pour cette application sp\u00e9cifique, nous proposons en outre\u00a0:<\/p>\n<ul>\n<li>No-excavation foundation kits: screws, anchors or ballast selected per ground condition<\/li>\n<li>Contaminated-land method statements with PPE and handling protocols<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"el-media-img\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/09\/pv-sub-brownfield-degraded-soil-pv-racking-2.jpg\" alt=\"Brownfield PV support solar racking - engineered structure detail\" loading=\"lazy\"><\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">M\u00e9thode d&#039;installation et productivit\u00e9 du site<\/h3>\n<div class=\"el-text\">\n<p>Renseignez-vous sur le mode d&#039;installation d&#039;une structure avant de comparer le prix de l&#039;acier. Nos syst\u00e8mes s&#039;installent avec des \u00e9quipements de construction standard\u00a0: aucun outil sp\u00e9cifique, aucune soudure sur site sur le chemin critique. Les pieux sont enfonc\u00e9s ou viss\u00e9s avec des engins conformes aux normes industrielles et des gabarits garantissent le respect des tol\u00e9rances d&#039;ancrage. Les tables sont livr\u00e9es pr\u00e9assembl\u00e9es en kits, selon votre plan d&#039;empilage. Le boulonnage \u00e0 couple contr\u00f4l\u00e9, avec les valeurs de couple fournies, remplace les assemblages soud\u00e9s. Les plages de r\u00e9glage des rails compensent les irr\u00e9gularit\u00e9s du terrain dues au nivellement. Nous fournissons des plans d&#039;installation, un manuel d&#039;installation d\u00e9taill\u00e9, des tableaux de couples et de tol\u00e9rances, ainsi qu&#039;une assistance \u00e0 distance pendant toute la dur\u00e9e de l&#039;installation. Sur demande, un superviseur d&#039;installation forme votre \u00e9quipe \u00e0 la pose des premiers blocs.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">R\u00e9f\u00e9rences sectorielles<\/h3>\n<div class=\"el-text\">\n<p>Les exemples ci-dessous sont des projets de r\u00e9f\u00e9rence industriels, document\u00e9s publiquement, de type et d&#039;envergure comparables, cit\u00e9s \u00e0 titre d&#039;illustration des pratiques d&#039;ing\u00e9nierie. Ils ne constituent pas un historique de nos r\u00e9alisations\u00a0; les r\u00e9f\u00e9rences correspondant \u00e0 votre configuration sont fournies avec les devis.<\/p>\n<ul class=\"el-two\">\n<li>A 6 GW-class composite base on Ningxia coal-mining subsidence land, converting deformed ground into PV land with monitoring and adjustable foundations. The landmark subsidence-area siting reference.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Normes et conformit\u00e9<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Landfill cap protection regulations (local; absolute requirement)<\/li>\n<li>Geotechnical settlement monitoring practice<\/li>\n<li>ISO 12944 coatings for contaminated and gaseous soils<\/li>\n<li>Structural ballast verification with bearing-limit documentation<\/li>\n<li>Gestion de la qualit\u00e9 de la production selon la norme ISO 9001\u00a0; tra\u00e7abilit\u00e9 des lots<\/li>\n<li>Documentation CE\/EN 1090 lorsque les march\u00e9s de destination l&#039;exigent<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Facteurs budg\u00e9taires et d\u00e9lais de livraison<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Ballast tonnage drives cost on caps: structure weight per MW matters more than steel price<\/li>\n<li>Adjustable-head systems add modest capex versus one re-leveling cycle avoided<\/li>\n<li>Monitoring commitments are opex; price them into the business case<\/li>\n<li>Lead time: 8-14 weeks; ballast supply logistics often set the pace<\/li>\n<li>Les devis pr\u00e9cisent la nuance d&#039;acier, la masse de zinc et le syst\u00e8me de rev\u00eatement\u00a0; les Incoterms et les plans de conteneur sont indiqu\u00e9s jusqu&#039;\u00e0 votre port de destination.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Comparaison des devis des fournisseurs<\/h3>\n<div class=\"el-text\">\n<p>Les devis pour un m\u00eame site peuvent diff\u00e9rer de 30 %, et il faut \u00eatre honn\u00eate\u00a0: la diff\u00e9rence r\u00e9side dans les hypoth\u00e8ses formul\u00e9es. Lors de la comparaison des offres, il est important de normaliser cinq \u00e9l\u00e9ments\u00a0: la nuance et le poids de l\u2019acier (des rails plus l\u00e9gers avec un espacement plus serr\u00e9 ne sont pas toujours plus \u00e9conomiques au m\u00e9gawatt lorsque le nombre de pieux augmente)\u00a0; la masse de zinc et le syst\u00e8me de rev\u00eatement en fonction de votre classe de corrosivit\u00e9\u00a0; la nature des fondations (pieux uniquement, ou pieux plus ancrages, semelles et mat\u00e9riel de terrassement)\u00a0; le mat\u00e9riel de connexion (classes de boulons et sp\u00e9cification des couples de serrage)\u00a0; et la logistique (utilisation des conteneurs, port de d\u00e9chargement et responsabilit\u00e9 du transport terrestre). Une offre mentionnant ces cinq \u00e9l\u00e9ments est comparable\u00a0; une offre qui les omet vous co\u00fbtera cher par la suite.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Foire aux questions<\/h2>\n<div class=\"el-acc\">\n<details>\n<summary>What foundation works on unpredictable brownfield ground?<\/summary>\n<div class=\"acc-body\">Screw piles and anchors adapt zone by zone, with ballast where penetration is impossible. The mix is priced from a legacy-features survey, not assumptions.<\/div>\n<\/details>\n<details>\n<summary>How is contamination handled during installation?<\/summary>\n<div class=\"acc-body\">No-excavation methods minimize soil contact; where soil is disturbed, handling protocols per your environmental report apply. The method statement is contract scope.<\/div>\n<\/details>\n<details>\n<summary>Do remediation schedules conflict with construction?<\/summary>\n<div class=\"acc-body\">They can be sequenced &#8211; remediated zones first, or zones without obligations. The phasing plan coordinates both timelines.<\/div>\n<\/details>\n<\/div>\n<h3 class=\"el-h\">Questions fr\u00e9quemment pos\u00e9es par les acheteurs<\/h3>\n<div class=\"el-acc\">\n<details>\n<summary>\u00c0 qui appartient la conception structurelle \u2013 pouvons-nous la modifier ?<\/summary>\n<div class=\"acc-body\">Des plans d&#039;atelier sp\u00e9cifiques \u00e0 votre projet sont fournis\u00a0; la structure sous-jacente demeure notre propri\u00e9t\u00e9 intellectuelle. Les modifications apport\u00e9es par le client sont les bienvenues et peuvent \u00eatre soumises \u00e0 notre bureau d&#039;\u00e9tudes \u2013 nous v\u00e9rifions le cheminement des charges et r\u00e9\u00e9ditons les plans concern\u00e9s \u2013 car toute modification non valid\u00e9e des rails ou des connexions sur le terrain annule la garantie et peut compromettre la conception.<\/div>\n<\/details>\n<details>\n<summary>Comment les modifications de commande sont-elles g\u00e9r\u00e9es en cours de production\u00a0?<\/summary>\n<div class=\"acc-body\">Les modifications sont chiffr\u00e9es en fonction du planning de production\u00a0: avant la d\u00e9coupe, \u00e0 un co\u00fbt quasi nul\u00a0; apr\u00e8s la d\u00e9coupe mais avant le rev\u00eatement, au co\u00fbt de remplacement du mat\u00e9riau\u00a0; apr\u00e8s la galvanisation, au co\u00fbt de refabrication. Chaque modification est confirm\u00e9e par \u00e9crit, avec une nouvelle date de livraison, avant sa mise en \u0153uvre. Ce processus vise \u00e0 garantir le respect des d\u00e9lais des deux parties, et notre registre des demandes de modification est joint au dossier de projet.<\/div>\n<\/details>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Que faut-il inclure dans votre demande de devis\u00a0?<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Environmental\/contamination report<\/li>\n<li>Legacy structure and foundation survey<\/li>\n<li>Remediation obligations and schedule<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">De la demande de devis \u00e0 la mise en service\u00a0: notre m\u00e9thode de travail<\/h3>\n<div class=\"el-text\">\n<p>Deux \u00e9l\u00e9ments sont d\u00e9terminants pour la r\u00e9ussite d&#039;une commande de rayonnages\u00a0: les accords pass\u00e9s avant la production et la documentation r\u00e9alis\u00e9e pendant celle-ci. Avant la production, nous nous accordons sur cinq points\u00a0: la conception structurelle, le type de fondation par zone de sol, la classe de protection contre la corrosion, l&#039;interface des modules et la s\u00e9quence de livraison. Pendant la production, chaque lot g\u00e9n\u00e8re des documents que vous pouvez remettre \u00e0 votre bailleur de fonds ou propri\u00e9taire sans traduction\u00a0: certificats d&#039;usine, mesures de rev\u00eatement, v\u00e9rification du couple de serrage, comptage des emballages. Apr\u00e8s la livraison, nous restons \u00e0 votre disposition\u00a0: assistance \u00e0 l&#039;installation, soutien lors de la premi\u00e8re inspection \u00e0 la r\u00e9ception et recommandations de pi\u00e8ces de rechange adapt\u00e9es \u00e0 la dur\u00e9e de vie de votre site, plut\u00f4t qu&#039;une liste de catalogue fixe. Interrogez nos anciens clients sur la mani\u00e8re dont les demandes de modification en cours de production ont \u00e9t\u00e9 g\u00e9r\u00e9es\u00a0; c&#039;est l\u00e0 le v\u00e9ritable test d&#039;un fournisseur.<\/p>\n<p>Envoyez vos documents \u00e0 notre bo\u00eete mail d&#039;ing\u00e9nierie\u00a0; un ing\u00e9nieur structure vous r\u00e9pondra sous un jour ouvr\u00e9 \u2013 pas un discours commercial, une r\u00e9ponse technique.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Qualit\u00e9, garantie et livraison<\/h3>\n<div class=\"el-text\">\n<p>Chaque lot est livr\u00e9 avec les certificats d&#039;usine, les relev\u00e9s d&#039;\u00e9paisseur de rev\u00eatement et les enregistrements de boulonnage\u00a0; les soudures sont conformes aux normes EN\u00a01090 ou AISC. La garantie structurelle est de 10\u00a0ans, avec une dur\u00e9e de vie pr\u00e9vue de 25 \u00e0 30\u00a0ans. Les kits de pi\u00e8ces d\u00e9tach\u00e9es sont document\u00e9s afin que les r\u00e9parations apr\u00e8s 12\u00a0ans ne d\u00e9pendent pas des informations recueillies la premi\u00e8re ann\u00e9e.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Documents que vous recevez<\/h3>\n<div class=\"el-text\">\n<p>Lors de la comparaison des fournisseurs, les acheteurs doivent \u00e9valuer la richesse de la documentation fournie, car les r\u00e9clamations sont faciles \u00e0 formuler, contrairement aux enregistrements. Nous fournissons\u00a0: des documents de conception d\u00e9taillant les normes, les cas de charge et les coefficients de s\u00e9curit\u00e9\u00a0; des enregistrements qualit\u00e9 par lot (acier, galvanisation, fixations) conserv\u00e9s pendant toute la dur\u00e9e de la garantie\u00a0; des manuels d\u2019installation et de maintenance destin\u00e9s aux \u00e9quipes sur site, et non \u00e0 des fins marketing\u00a0; des conditions de garantie pr\u00e9cisant les \u00e9l\u00e9ments couverts, leur dur\u00e9e et la proc\u00e9dure de r\u00e9clamation\u00a0; et des dossiers de fin de projet pr\u00eats \u00e0 \u00eatre remis \u00e0 votre prestataire d\u2019exploitation et de maintenance. Pour les acheteurs r\u00e9alisant plusieurs projets, nous conservons un historique documentaire par site, permettant ainsi aux extensions de garantie de huit ans de se baser sur les hypoth\u00e8ses de la premi\u00e8re ann\u00e9e, et non de repartir de z\u00e9ro.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Dur\u00e9e de vie et planification de la maintenance<\/h2>\n<div class=\"el-text\">\n<p>L&#039;installation de rayonnages est un investissement \u00e0 trente ans, et la premi\u00e8re intervention de maintenance r\u00e9v\u00e8le le co\u00fbt exorbitant des \u00e9quipements bon march\u00e9. Nous concevons des syst\u00e8mes de rev\u00eatement adapt\u00e9s \u00e0 la classe de corrosivit\u00e9 de votre site\u00a0: C2 pour les zones int\u00e9rieures s\u00e8ches, C3-C4 pour la plupart des zones c\u00f4ti\u00e8res et agricoles, C5 pour les environnements industriels et marins \u00e0 forte exposition. Nous vous communiquons par \u00e9crit le d\u00e9lai pr\u00e9vu avant la premi\u00e8re maintenance. Le choix des boulons suit la m\u00eame logique\u00a0: fixations haute r\u00e9sistance rev\u00eatues, \u00e0 couple de serrage contr\u00f4l\u00e9, car l&#039;utilisation de mat\u00e9riel h\u00e9t\u00e9rog\u00e8ne est la cause la plus fr\u00e9quente de corrosion pr\u00e9coce lors des inspections sur site. Un kit de pi\u00e8ces de rechange adapt\u00e9 \u00e0 votre environnement est livr\u00e9 avec la commande.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Termes de recherche pour lesquels cette page est con\u00e7ue<\/h2>\n<div class=\"el-text\">\n<p>brownfield PV support, degraded soil solar mount, waste dump PV support, restored land photovoltaic racking, solar bracket for brownfield site.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec el-cta\" style=\"background-color:#0097B4;\">\n<h2 class=\"el-h\">Pr\u00eat \u00e0 discuter de votre projet ?<\/h2>\n<div class=\"el-text\">\n<p>Send the environmental report &#8211; we will return a no-excavation foundation plan with the method statements that satisfy your regulator.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/fr\/contact-us\/#contactpopupform\">Demander un devis<\/a><\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Specifying Brownfield solar racking? This page shows which configuration fits your site, what drives delivered cost, and which QA evidence to demand.<\/p>","protected":false},"author":1,"featured_media":3311,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[354,319],"tags":[356],"class_list":["post-3910","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-brownfield-reclaimed-post-mining-solar-projects","category-site-types","tag-reclaimed-brownfield-long-tail-page-pv-mounting-system"],"_links":{"self":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts\/3910","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/comments?post=3910"}],"version-history":[{"count":0,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts\/3910\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/media\/3311"}],"wp:attachment":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/media?parent=3910"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/categories?post=3910"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/tags?post=3910"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}