{"id":3906,"date":"2026-08-05T19:02:00","date_gmt":"2026-08-05T11:02:00","guid":{"rendered":"https:\/\/ksnrsolar.com\/reservoir-lakeshore-dam-crest-pv-mounting\/"},"modified":"2026-08-05T19:02:00","modified_gmt":"2026-08-05T11:02:00","slug":"reservoir-lakeshore-dam-crest-pv-mounting","status":"publish","type":"post","link":"https:\/\/ksnrsolar.com\/fr\/reservoir-lakeshore-dam-crest-pv-mounting\/","title":{"rendered":"Reservoir-Surface, Lake-Shore and Dam-Crest Photovoltaic Racking Solutions"},"content":{"rendered":"<style>\n.el-sec{background:#fff;border-radius:8px;box-shadow:0 1px 4px rgba(20,40,80,.08);padding:34px 42px;margin:0 auto 22px;max-width:1020px;box-sizing:border-box}\n.el-h{color:#1E293B;margin:0 0 14px}\nh2.el-h{font-size:26px;text-align:center;border-left:none;padding-left:0;line-height:1.3;margin-bottom:22px}\nh2.el-h::after{content:'';display:block;width:60px;height:3px;background:#F9960E;margin:12px auto 0;border-radius:2px}\nh3.el-h{font-size:19px}\n.el-hero{padding:0;overflow:hidden}\n.el-overlay{padding:48px 38px;text-align:center}\n.el-overlay .el-check{display:inline-block;text-align:left}\n.el-row{display:flex;gap:16px;align-items:stretch;flex-wrap:wrap}\n.el-col{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;box-sizing:border-box}\n.el-btn{display:inline-block;background:#0097B4;color:#fff !important;padding:10px 26px;border-radius:5px;text-decoration:none;font-weight:600;font-size:15px}\n.el-check{list-style:none;margin:10px 0;padding:0}\n.el-check li{padding:5px 0 5px 26px;position:relative}\n.el-check li::before{content:'\u2713';position:absolute;left:2px;color:#1E8A5F;font-weight:700}\n.el-box{background:#F0F5FA;border:1px solid #D1D5DB;border-radius:6px;padding:16px 18px;margin:8px 0}\n.el-box-icon{font-size:24px;margin-bottom:6px}\n.el-box h4{color:#1E293B;margin:0 0 6px;font-size:16px}\n.el-box p{font-size:14px;color:#334155;margin:0}\n.el-acc details{border:1px solid #D1D5DB;border-radius:6px;margin:0 0 10px;background:#F9FAFB}\n.el-acc summary{padding:13px 18px;cursor:pointer;font-weight:600;color:#1E293B}\n.acc-body{padding:4px 18px 14px;font-size:14.5px;color:#334155}\n.el-cta{text-align:center}\n.el-cta .el-h{color:#fff;border-left:none;padding-left:0}\n.el-cta .el-btn{background:#1E293B}.el-cta .el-text{color:#fff}.el-cta .el-text p{color:rgba(255,255,255,.92)}\n.el-sec table{width:100%;border-collapse:collapse;margin:12px 0;font-size:14.5px}\n.el-sec th,.el-sec td{border:1px solid #D1D5DB;padding:9px 12px;text-align:left;vertical-align:top}\n.el-sec th{background:#F0F5FA;color:#1E293B}\n.el-text p{margin:0 0 10px}\n.el-text ul{margin:0 0 10px 22px}\n.el-text a{color:#0097B4}\n.el-band{background:#F0F5FA;border-radius:8px;max-width:1020px;margin:0 auto 22px;padding:18px 30px;font-size:15px;box-sizing:border-box}\n.el-band p{margin:0}\n.el-media{display:flex;gap:30px;align-items:center}\n.el-media.rev{flex-direction:row-reverse}\n.el-media-txt{flex:1.15;min-width:0}\n.el-media-img{flex:1;min-width:0}\n.el-media-img img{width:100%;height:auto;display:block;border-radius:8px;box-shadow:0 2px 10px rgba(20,40,80,.14)}\nul.el-two{column-count:2;column-gap:44px}\nul.el-two li{break-inside:avoid}\n@media (max-width:767px){.el-row{flex-direction:column}.el-col{flex:none !important;max-width:100% !important}.el-sec{padding:22px 18px}.el-overlay{padding:32px 20px}.el-media,.el-media.rev{flex-direction:column;align-items:stretch}ul.el-two{column-count:1}.el-band{padding:14px 18px}}\n.el-btn:hover{background:#F9960E}<\/style>\n<section class=\"el-sec el-hero\" style=\"background-image:url(\/wp-content\/uploads\/2026\/09\/pv-sub-reservoir-lakeshore-dam-crest-pv-mounting-1.jpg);background-size:cover;background-position:center;\">\n<div class=\"el-overlay\" style=\"background:rgba(255,255,255,0.82);\">\n<h2 class=\"el-h\">Reservoir-Surface, Lake-Shore and Dam-Crest Photovoltaic Racking Solutions<\/h2>\n<div class=\"el-text\">\n<p>Reservoir, lakeshore and dam-crest mounting works around water that moves: drawdown zones cycle dry to submerged, dam owners impose safety zones, and flood releases change shoreline geometry. This page covers edge-mounting engineering where the reservoir sets the rules.<\/p>\n<p>The content below serves developers, EPC contractors and owner engineers specifying structures for River \/ Reservoir \/ Canal installations.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/fr\/contact-us\/#contactpopupform\">Obtenez un devis rapide<\/a><\/p>\n<\/div>\n<\/section>\n<div class=\"el-band\">\n<div class=\"el-text\">\n<p>This page is one of several in our river \/ reservoir \/ canal segment. See the full range of structures, foundations and configurations on the <a href=\"\/fr\/waterfront-solar-projects\/\">PV Racking for Canals, Reservoirs, Lakeshores &#038; Riversides<\/a> Page centrale.<\/p>\n<\/div>\n<\/div>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Why River \/ Reservoir \/ Canal sites are demanding<\/h2>\n<div class=\"el-text\">\n<p>Canals, reservoirs and rivers offer land-free PV over water that already serves irrigation, flood or power purposes. The engineering split is threefold: canal-top spans that keep water flowing, reservoir-edge mounting that survives drawdown, and riverside arrays on flood-tolerant foundations.<\/p>\n<p><strong>D\u00e9fis du site que nous relevons par la conception\u00a0:<\/strong><\/p>\n<\/div>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>D\u00e9fi 01<\/h4>\n<p>Humid, reflective environments accelerate corrosion at splash lines<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 02<\/h4>\n<p>Canal spans must keep clearance for flow, maintenance craft and debris passage<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 03<\/h4>\n<p>Reservoir drawdown zones cycle from dry to submerged; foundations and coatings must tolerate both<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u26a1<\/div>\n<h4>D\u00e9fi 04<\/h4>\n<p>Flood events drive debris impact and scour on riverside arrays<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\">\u25a6<\/div>\n<h4>D\u00e9fi 05<\/h4>\n<p>Drawdown cycles destroy underspecified coatings and foundations<\/p>\n<\/div>\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 06<\/h4>\n<p>Dam safety zones restrict where anything may be built<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-row\">\n<div class=\"el-box\">\n<div class=\"el-box-icon\"> <\/div>\n<h4>D\u00e9fi 07<\/h4>\n<p>Flood releases scour and rework shorelines unpredictably<\/p>\n<\/div>\n<\/div>\n<\/section>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Exigences techniques et base de conception<\/h2>\n<ul class=\"el-check\">\n<li>Scour assessment and foundation depth below predicted scour line<\/li>\n<li>Flood-aware cable routing above design flood level<\/li>\n<li>Mooring or anchoring design reviewed against water-authority requirements<\/li>\n<li>Span structures across canals: anchor beams, braced portals with debris deflectors<\/li>\n<\/ul>\n<div class=\"el-text\">\n<p><strong>Conseils de s\u00e9lection\u00a0:<\/strong> Map the drawdown envelope first, then assign coating classes per zone; require dam-authority zone drawings before layout freezes.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<div class=\"el-media\">\n<div class=\"el-media-txt\">\n<h3 class=\"el-h\">Solution technique<\/h3>\n<div class=\"el-text\">\n<ul>\n<li>Scour-protective detailing: deeper embedment, collars, riprap coordination<\/li>\n<li>Water-authority documentation package: anchoring plans, water-quality statements<\/li>\n<li>Debris-deflection geometry on upstream faces<\/li>\n<li>Maintenance access: walkways or boat-based cleaning strategies designed in<\/li>\n<li>Canal-top span packages engineered to the specific channel geometry and clearance rules<\/li>\n<\/ul>\n<p>Pour cette application sp\u00e9cifique, nous proposons en outre\u00a0:<\/p>\n<ul>\n<li>Cyclic-immersion coating classes with drawdown-zone detailing<\/li>\n<li>Dam-authority coordination: safety zones and approval documents built into the plan<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"el-media-img\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/09\/pv-sub-reservoir-lakeshore-dam-crest-pv-mounting-2.jpg\" alt=\"Reservoir surface PV mounting solar racking - engineered structure detail\" loading=\"lazy\"><\/div>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">M\u00e9thode d&#039;installation et productivit\u00e9 du site<\/h3>\n<div class=\"el-text\">\n<p>La m\u00e9thode d&#039;installation est un poste de d\u00e9pense \u00e0 part enti\u00e8re, et non une simple formalit\u00e9. Nous livrons des structures con\u00e7ues sp\u00e9cifiquement pour l&#039;\u00e9quipement dont vous disposerez : des engins de battage de pieux avec gabarits adapt\u00e9s aux sols acceptant les pieux battus ; des engins de battage de pieux viss\u00e9s avec contr\u00f4le du couple lorsque le refus ou les vibrations emp\u00eachent l&#039;impact ; des ballasts pr\u00e9fabriqu\u00e9s lorsque la p\u00e9n\u00e9tration est interdite ; et un assemblage de tables par boulonnage uniquement, avec plus de 80 % de pr\u00e9fabrication en atelier, ce qui \u00e9limine tout besoin de soudure sur site. La productivit\u00e9 des \u00e9quipes est g\u00e9n\u00e9ralement de 40 \u00e0 80 tables par jour et par engin sur les zones pr\u00e9par\u00e9es. Notre manuel d&#039;installation indique la taille d&#039;\u00e9quipe pr\u00e9vue, la liste des \u00e9quipements et la production journali\u00e8re, afin que votre planning de construction soit bas\u00e9 sur des donn\u00e9es chiffr\u00e9es, et non sur de l&#039;optimisme.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">R\u00e9f\u00e9rences sectorielles<\/h3>\n<div class=\"el-text\">\n<p>Les exemples ci-dessous sont des projets de r\u00e9f\u00e9rence industriels, document\u00e9s publiquement, de type et d&#039;envergure comparables, cit\u00e9s \u00e0 titre d&#039;illustration des pratiques d&#039;ing\u00e9nierie. Ils ne constituent pas un historique de nos r\u00e9alisations\u00a0; les r\u00e9f\u00e9rences correspondant \u00e0 votre configuration sont fournies avec les devis.<\/p>\n<ul class=\"el-two\">\n<li>A 278 MW-class floating plant on a large reservoir in Madhya Pradesh, among Asia&#8217;s largest, with HDPE floats and moorings sized for monsoon reservoir dynamics.<\/li>\n<li>Un micror\u00e9seau photovolta\u00efque de p\u00eache sur l&#039;\u00eele de Chishan \u00e0 Yuanjiang, Hunan, combinant des bassins photovolta\u00efques avec un stockage insulaire pour les charges locales.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Normes et conformit\u00e9<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Water-authority and navigation regulations (project-specific)<\/li>\n<li>ISO 12944 Im2\/Im3 immersion-zone coating classes<\/li>\n<li>EN 1991 \/ ASCE 7 wind plus debris-impact provisions where mapped<\/li>\n<li>Scour assessment per hydraulic engineering practice<\/li>\n<li>Gestion de la qualit\u00e9 de la production selon la norme ISO 9001\u00a0; tra\u00e7abilit\u00e9 des lots<\/li>\n<li>Documentation CE\/EN 1090 lorsque les march\u00e9s de destination l&#039;exigent<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Facteurs budg\u00e9taires et d\u00e9lais de livraison<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Span structures cost 2-3x ground-mounted equivalents per MW but use zero land<\/li>\n<li>Drawdown-zone coatings add 5-10 percent; underspecifying them drives repaint cycles<\/li>\n<li>Scour protection is priced with hydraulic data, not assumptions<\/li>\n<li>Lead time: 10-16 weeks for engineered spans; piles and coatings 8-12 weeks<\/li>\n<li>Les devis pr\u00e9cisent la nuance d&#039;acier, la masse de zinc et le syst\u00e8me de rev\u00eatement\u00a0; les Incoterms et les plans de conteneur sont indiqu\u00e9s jusqu&#039;\u00e0 votre port de destination.<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Comparaison des devis des fournisseurs<\/h3>\n<div class=\"el-text\">\n<p>Les devis pour un m\u00eame site peuvent diff\u00e9rer de 30 %, et il faut \u00eatre honn\u00eate\u00a0: la diff\u00e9rence r\u00e9side dans les hypoth\u00e8ses formul\u00e9es. Lors de la comparaison des offres, il est important de normaliser cinq \u00e9l\u00e9ments\u00a0: la nuance et le poids de l\u2019acier (des rails plus l\u00e9gers avec un espacement plus serr\u00e9 ne sont pas toujours plus \u00e9conomiques au m\u00e9gawatt lorsque le nombre de pieux augmente)\u00a0; la masse de zinc et le syst\u00e8me de rev\u00eatement en fonction de votre classe de corrosivit\u00e9\u00a0; la nature des fondations (pieux uniquement, ou pieux plus ancrages, semelles et mat\u00e9riel de terrassement)\u00a0; le mat\u00e9riel de connexion (classes de boulons et sp\u00e9cification des couples de serrage)\u00a0; et la logistique (utilisation des conteneurs, port de d\u00e9chargement et responsabilit\u00e9 du transport terrestre). Une offre mentionnant ces cinq \u00e9l\u00e9ments est comparable\u00a0; une offre qui les omet vous co\u00fbtera cher par la suite.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Foire aux questions<\/h2>\n<div class=\"el-acc\">\n<details>\n<summary>What coating survives drawdown cycling?<\/summary>\n<div class=\"acc-body\">Im2-class systems rated for immersion and exposure cycling, with first-maintenance estimates. Standard atmospheric coatings fail within a few seasons at the waterline.<\/div>\n<\/details>\n<details>\n<summary>How do dam safety zones affect layout?<\/summary>\n<div class=\"acc-body\">Authority drawings define exclusion and monitoring zones; our layout respects them and the approval package references them explicitly.<\/div>\n<\/details>\n<details>\n<summary>Is scour a real risk at lakeshore arrays?<\/summary>\n<div class=\"acc-body\">At release-affected shorelines yes &#8211; embedment is set below predicted scour with protection where the model says so. We need the release regime data.<\/div>\n<\/details>\n<\/div>\n<h3 class=\"el-h\">Questions fr\u00e9quemment pos\u00e9es par les acheteurs<\/h3>\n<div class=\"el-acc\">\n<details>\n<summary>Proposez-vous une formation \u00e0 l&#039;installation sur site\u00a0?<\/summary>\n<div class=\"acc-body\">Oui. Nous assurons l&#039;installation supervis\u00e9e des premiers blocs, la formation du personnel conform\u00e9ment au manuel d&#039;installation et des revues de conformit\u00e9 avec vos ing\u00e9nieurs sur site. Pour les sites isol\u00e9s, nous proposons des sessions de supervision \u00e0 distance avec analyse vid\u00e9o des premi\u00e8res tables assembl\u00e9es. Le contenu et la dur\u00e9e de la formation sont pr\u00e9cis\u00e9s dans le contrat de fourniture.<\/div>\n<\/details>\n<details>\n<summary>De quelles informations avez-vous besoin pour que votre devis reste valable\u00a0?<\/summary>\n<div class=\"acc-body\">Les devis sont bas\u00e9s sur des hypoth\u00e8ses de prix de l&#039;acier pour une p\u00e9riode donn\u00e9e, g\u00e9n\u00e9ralement de 20 \u00e0 30 jours. Leur validit\u00e9 est prolong\u00e9e lorsque les donn\u00e9es d&#039;entr\u00e9e sont stables\u00a0: vitesse du vent et terrain de conception confirm\u00e9s, donn\u00e9es g\u00e9otechniques, mod\u00e8le de module et quantit\u00e9s. En cas de modification d&#039;une donn\u00e9e, seuls les postes concern\u00e9s sont mis \u00e0 jour (\u00e9tendue des fondations, classe de rev\u00eatement ou tonnage d&#039;acier), ce qui permet de conserver la tra\u00e7abilit\u00e9 de la comparaison.<\/div>\n<\/details>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Que faut-il inclure dans votre demande de devis\u00a0?<\/h3>\n<div class=\"el-text\">\n<ul class=\"el-two\">\n<li>Drawdown envelope and release regime<\/li>\n<li>Dam-authority zone drawings<\/li>\n<li>Shoreline soil and scour data<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">De la demande de devis \u00e0 la mise en service\u00a0: notre m\u00e9thode de travail<\/h3>\n<div class=\"el-text\">\n<p>Une mission type se d\u00e9roule en cinq \u00e9tapes\u00a0: (1) Examen de la demande de devis\u00a0: nous v\u00e9rifions les plans, les rapports g\u00e9otechniques et les hypoth\u00e8ses de charge avant d\u2019\u00e9tablir le devis, et nous signalons les \u00e9ventuelles lacunes susceptibles d\u2019entra\u00eener des co\u00fbts suppl\u00e9mentaires\u00a0; (2) Proposition\u00a0: base structurelle, bordereau des quantit\u00e9s, options de fondation et Incoterms pr\u00e9sent\u00e9s c\u00f4te \u00e0 c\u00f4te\u00a0; (3) Gel des sp\u00e9cifications techniques\u00a0: essais de pieux ou essais de pr\u00e9-forage lorsque les sols l\u2019exigent, validation des plans d\u2019ex\u00e9cution par les deux \u00e9quipes d\u2019ing\u00e9nierie\u00a0; (4) Production\u00a0: \u00e9mission des documents d\u2019assurance qualit\u00e9 par lot, inspection avant exp\u00e9dition ouverte \u00e0 votre inspecteur ou \u00e0 un tiers\u00a0; (5) Assistance \u00e0 la livraison et \u00e0 l\u2019installation\u00a0: plans des conteneurs adapt\u00e9s \u00e0 la s\u00e9quence EPC, manuels d\u2019installation, tableaux de couples de serrage et guide de mise en service. Chaque \u00e9tape donne lieu \u00e0 un document que vous pouvez archiver\u00a0; nos clients nous disent que la rigueur du processus est plus importante que les brochures.<\/p>\n<p>Envoyez vos documents \u00e0 notre bo\u00eete mail d&#039;ing\u00e9nierie\u00a0; un ing\u00e9nieur structure vous r\u00e9pondra sous un jour ouvr\u00e9 \u2013 pas un discours commercial, une r\u00e9ponse technique.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Qualit\u00e9, garantie et livraison<\/h3>\n<div class=\"el-text\">\n<p>Nous contr\u00f4lons la qualit\u00e9 \u00e0 trois \u00e9tapes\u00a0: certification de l\u2019acier \u00e0 r\u00e9ception, contr\u00f4les dimensionnels avant assemblage sur gabarits et v\u00e9rification de l\u2019\u00e9paisseur apr\u00e8s galvanisation pour chaque lot. Les conditions de garantie sont bas\u00e9es sur des cas de charge et des environnements sp\u00e9cifiques, et non sur des adjectifs\u00a0; n\u2019h\u00e9sitez pas \u00e0 nous demander de pr\u00e9senter les documents \u00e0 votre \u00e9quipe d\u2019assurance qualit\u00e9 avant l\u2019attribution du contrat.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h3 class=\"el-h\">Documents que vous recevez<\/h3>\n<div class=\"el-text\">\n<p>Lors de la comparaison des fournisseurs, les acheteurs doivent \u00e9valuer la richesse de la documentation fournie, car les r\u00e9clamations sont faciles \u00e0 formuler, contrairement aux enregistrements. Nous fournissons\u00a0: des documents de conception d\u00e9taillant les normes, les cas de charge et les coefficients de s\u00e9curit\u00e9\u00a0; des enregistrements qualit\u00e9 par lot (acier, galvanisation, fixations) conserv\u00e9s pendant toute la dur\u00e9e de la garantie\u00a0; des manuels d\u2019installation et de maintenance destin\u00e9s aux \u00e9quipes sur site, et non \u00e0 des fins marketing\u00a0; des conditions de garantie pr\u00e9cisant les \u00e9l\u00e9ments couverts, leur dur\u00e9e et la proc\u00e9dure de r\u00e9clamation\u00a0; et des dossiers de fin de projet pr\u00eats \u00e0 \u00eatre remis \u00e0 votre prestataire d\u2019exploitation et de maintenance. Pour les acheteurs r\u00e9alisant plusieurs projets, nous conservons un historique documentaire par site, permettant ainsi aux extensions de garantie de huit ans de se baser sur les hypoth\u00e8ses de la premi\u00e8re ann\u00e9e, et non de repartir de z\u00e9ro.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Dur\u00e9e de vie et planification de la maintenance<\/h2>\n<div class=\"el-text\">\n<p>Planifiez la maintenance en fonction d&#039;indicateurs mesurables, et non de simples estimations calendaires. Effectuez une inspection visuelle annuelle des \u00e9chantillons de couple de serrage des fixations, de l&#039;\u00e9tat du rev\u00eatement sur les bords coup\u00e9s et les zones de contact avec le sol\u00a0; une inspection d\u00e9taill\u00e9e est requise apr\u00e8s la premi\u00e8re ann\u00e9e de conditions m\u00e9t\u00e9orologiques extr\u00eames (typhon, temp\u00eate de sable ou fortes chutes de neige, selon votre r\u00e9gion)\u00a0; un resserrage est n\u00e9cessaire apr\u00e8s le premier cycle thermique sur les syst\u00e8mes de suivi de longue dur\u00e9e. Nous fournissons la liste de contr\u00f4le d&#039;inspection et les crit\u00e8res d&#039;acceptation avec le manuel d&#039;installation, afin que votre \u00e9quipe d&#039;exploitation et de maintenance effectue les mesures selon les m\u00eames valeurs que celles utilis\u00e9es en usine. Lorsque les structures sont install\u00e9es sur des sols agressifs ou en zones salines, nous recommandons une masse de zinc plus importante et un syst\u00e8me de drainage plus performant d\u00e8s la conception \u2013 une solution plus \u00e9conomique que les modifications ult\u00e9rieures.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec\">\n<h2 class=\"el-h\">Termes de recherche pour lesquels cette page est con\u00e7ue<\/h2>\n<div class=\"el-text\">\n<p>reservoir surface PV mounting, lake shore PV mounting, dam crest photovoltaic racking, embankment solar support, solar mounting for reservoir surface, PV mounting for floodplain, solar bracket for levee embankment, PV racking for dam crest.<\/p>\n<\/div>\n<\/section>\n<section class=\"el-sec el-cta\" style=\"background-color:#0097B4;\">\n<h2 class=\"el-h\">Pr\u00eat \u00e0 discuter de votre projet ?<\/h2>\n<div class=\"el-text\">\n<p>Send drawdown and authority data &#8211; we will return a zone-mapped coating and foundation plan that survives the reservoir&#8217;s calendar.<\/p>\n<\/div>\n<p><a class=\"el-btn\" href=\"\/fr\/contact-us\/#contactpopupform\">Demander un devis<\/a><\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Specifying Reservoir surface solar racking? This page shows which configuration fits your site, what drives delivered cost, and which QA evidence to demand.<\/p>","protected":false},"author":1,"featured_media":3421,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[351,319],"tags":[352],"class_list":["post-3906","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-canal-reservoir-waterfront-solar-projects","category-site-types","tag-canal-reservoir-core-page-pv-mounting-system"],"_links":{"self":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts\/3906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/comments?post=3906"}],"version-history":[{"count":0,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/posts\/3906\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/media\/3421"}],"wp:attachment":[{"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/media?parent=3906"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/categories?post=3906"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ksnrsolar.com\/fr\/wp-json\/wp\/v2\/tags?post=3906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}